Over 25,000
ELC units in operation !!!



Typical Dynamic clearances

Component Clearance (microns)
Roller Element Bearings 0.1 - 1
Journal Bearings 0.5 - 100
Hydraulic Bearings 1 - 25
Gears 0.1 - 1
Dynamic Seal 0.05 - 0.5
Pump, Gear  
Tooth to Side Plate 0.5 -5
Tooth tip to Case 0.5 -5
Pump, Vane  
Vane Sides 5 - 13
Vane Tip 0.5 - 1
Pump, Piston  

Piston to Bore

5 - 40
Valve Plate to Cylinder 0.5 - 5
Servo Valves  
Orifice 130 - 450
Flapper Wall 18 - 63
Spool to Sleeve 1 - 4

Source : ASME Wear control handbook, 1981

 