Ferrocare Machines Pvt. Ltd.
About Us Technology Location Customers FAQs Contact Home FMPL

Products



Principle of operation

ELC

LVDH

Magnetix

Response




Over 25,000
ELC units in operation !!!


We have a range of products to suit every need.
The model selection criteria depends on

  • Fluid Volume
  • Fluid Viscosity
  • Application
  • Sophistication of the hydraulic system i.e.
    A) Servo valves
    B) Proportional valves etc.

Selection guide as per our catalogue for dedication

             
  Selection Guide  
  Conventional Hydraulics (max. quantity)  
 


Type

32 CST 46 CST 68 CST 100 CST  
  ELC 8LP 2500 Litres 1700 Litres 1100 Litres 600 Litres  
  ELC 25A 6000 Litres 4200 Litres 2800 Litres 1500 Litres  
  ELC 50C 12000 Litres 8300 Litres 5600 Litres 3000 Litres  
  ELC 100LP 30000 Litres 20000 Litres 14000 Litres 7600 Litres  
             

For NAS 7 & below, max quantity would be 1/2 to 1/3 rd of the table value.

1) Electrostatic Liquid Cleaner - ELC 8 LP    
 
 

Specification Chart

ELC 8 LP  
Dimension (LxWxH) in mm 610 x 500 x 535
Weight 70 kg.
Pump Flow Rate 2 LPM at 50 Hz.
Power Consumption 250 W
Input Power Supply 3 Phase 440 V/ Single phase 220 V (Optional)
 
       
2) Electrostatic Liquid Cleaner - ELC 25 A    
 
 

Specification Chart

ELC 25 A  
Dimension (LxWxH) in mm 750 x 500 x 720
Weight 110 kg.
Pump Flow Rate 3-5 LPM at 50 Hz.
Power Consumption 250 W
Input Power Supply 3 Phase 440 V/ Single phase 220 V (Optional)
 
       
3) Electrostatic Liquid Cleaner - ELC 50 C    
 
 

Specification Chart

ELC 50 LP  
Dimension (LxWxH) in mm 750 x 500 x 720
Weight 110 kg.
Pump Flow Rate 12 LPM at 50 Hz.
Power Consumption 250 W
Input Power Supply 3 Phase 440 V/ Single phase 220 V (Optional)
 
       
4) Electrostatic Liquid Cleaner - ELC 100 LP    
 
 

Specification Chart

ELC 100 LP  
Dimension (LxWxH) in mm 900 x 615 x 920
Weight 181 kg.
Pump Flow Rate 12 LMP 50 Hz.
Power Consumption 600 W
Input Power Supply 3 Phase 440 V/ Single phase 220 V (Optional)
 
       
5) Low Vacuum Dehydration & Degassification - LVDH 50    
 
 

Specification Chart

LVDH 50  
Dimension (LxWxH) in mm 1170 x 1050 x 660
Weight 250 kg.
Pump Flow Rate Vacuum 150 LPM
Power Consumption 7 kWh
Input Power Supply 3 Phase 440 V 50 Hz.
 
       
  Helping you ... Work better... Under Pressure.....